Well-designed CV-709 silicone sealant for PV moudels to Chile Manufacturers
Short Description:
Description CV709 is a high-performance silicone sealant, one-component oxime type room temperature curing silicone rubber, has excellent weather resistance, high thixotropy, after curing for solar components involved in the base material has good caking property, by TUV for environmental requirements of the ROHS, UL E339949 Key Features 1. 100% silicone 2. No sag 3. high thixotropy 4. Water & weatherproof 5. For solar components involved in the base material has good bonding Basic Ap...
Sticking to the belief of "Creating products of high quality and making friends with people from all over the world", we always put the interest of customers in the first place for Well-designed CV-709 silicone sealant for PV moudels to Chile Manufacturers, Inspired by the rapid developing market of the fast food and beverage consumables all over the world , We are looking forward to working with partners /clients to make success together .
Description
CV709 is a high-performance silicone sealant, one-component oxime type room temperature curing silicone rubber, has excellent weather resistance, high thixotropy, after curing for solar components involved in the base material has good caking property, by TUV for environmental requirements of the ROHS, UL E339949
Key Features
1. 100% silicone
2. No sag
3. high thixotropy
4. Water & weatherproof
5. For solar components involved in the base material has good bonding
Basic Application
1.Solar module frame seal
2.The adhesive of the solar energy back to the terminal block
3.General industrial assembly with seal
Technical data sheet
Test standard | Test project | Unit | value |
Before curing——25℃,50%R.H. | |||
specific gravity | g/ml | 1.34-1.40 | |
GB13477 | Operating time | min | 15 |
GB13477 | surface drying time(25℃,50%R.H.) | min | 40-60 |
3 days after curing——25℃,50%R.H. | |||
Temperature range | ℃ | -55~200 | |
GB13477 | Durometer Hardness | Shore A | 40~55 |
The ultimate tensile strength | Mpa | ≥2 | |
GB13477 | Breaking elongation | % | 300-600 |
Aluminum bonding shear strength | Mpa | ≥1.5 | |
Electrical properties | |||
Breakdown voltage | Kv/mm | ≥20 | |
Volume resistance | ohm.cm | 9E+14 | |
Dielectric constant | 3.1@50Hz |
Certification
UL E339949; TUV
Color
Black, White
Package
300ml in cartridge * 24 per box, 500ml in sausage *20 per box
Shelf life
12 months
Note
If you want the TDS or MSDS or other details, please contact with our sales person.
GAF- Mastering The Roof (chapter 14)
The Liberty™ System is designed for both new roofing and re-roofing applications.
Full Installation Guide for Low Slope Modified Roofing (Cold-Applied Liberty System).
Low Slope Roofing Systems such as Liberty should only be installed on roof slopes of 2 in 12″ or higher. Never install it on roofs with ponding water.
This guide covers following procedures:
Deck Preparation
Base Ply Install
Middle Ply Install
Cap Sheet Installation
Drip Edge, Flashing and Accessory Installation details.
Low slope areas such as the roofs of carports, garages, porches and sun rooms – anything below a 2/12 pitch requires special attention.
Without the drainage of a steep slope, these roofs can take a hard beating from rain, ice and snow.
You’ve probably seen the problem leaks that occur where these low slope roofs tie in with the main house.
To provide you with materials that can meet these challenges, GAF has developed a series of self adhering membranes that go down easy, apply with simple tools and provide maximum protection. Lets take a look at these revolutionary low slope products and see how they install.
Liberty is a system for low slopes with a pitch between 1/2” to 6” per foot. Designed as a Whether installing Liberty Mechanically Attached Base Sheet, or Liberty Self Adhered Base Sheet, your edge metal details are the same.
At the edge of the roof, install drip edges. Primed Metal drip edge is required at eaves and rakes on Liberty Systems. At eaves and rakes, install a bed of Topcoat® Matrix 201 Premium SBS Flashing Cement to set the metal drip edge into. Next, to better seal the flange to the Base Sheet Base/Ply, nail the drip edge 3” on centers in a staggered pattern using roofing nails. Finally, apply a 1/16 to 1/8 inch troweling of Matrix 201 Premium SBS Flashing Cement to the top of the metal prior to installing the Liberty Cap Sheet over drip edges. Using a notched trowel helps assure a proper application rate of adhesive.
Working from the center of the length of Base Ply Sheet, allow the sheet to roll onto the primed deck, being careful to avoid wrinkles and trapped air while maintaining proper alignment with the selvage edge of the previous course.
Firmly hand press the sheet to avoid wrinkles and trapped air as the Base/Ply adheres to the underlying base sheet or primed deck.
Now fold the other half of the sheet back on itself exposing the remaining release film. Remove the release film and roll the sheet in place working from the center of the sheet outward towards the ends of the sheet.
Flashing of walls, roof terminations and penetrations can also be done with Liberty membranes and pre-flashed, SBS M-Weld Units.
As with all vertical flashings, the flashing is nailed off at the top and counter flashed.
Talent On Camera
Liberty is just one of the self-adhered products offered by GAF. Others include the Freedom series of self-adhered TPO roofing membranes.
Freedom membrane is a tough commercial grade membrane that is easy to install, long lasting and energy efficient with a white reflective surface. For further information on self adhered roofing technology, visit GAF.com or call 1-800-ROOF-411. That’s 1-800-766-3411.
Polyurethane grout injection