OEM Supplier for SV-777 silicone sealant for stone for luzern Factory

OEM Supplier for SV-777 silicone sealant for stone for luzern Factory
  • OEM Supplier for SV-777 silicone sealant for stone for luzern FactoryOEM Supplier for SV-777 silicone sealant for stone for luzern Factory
  • OEM Supplier for SV-777 silicone sealant for stone for luzern FactoryOEM Supplier for SV-777 silicone sealant for stone for luzern Factory
  • OEM Supplier for SV-777 silicone sealant for stone for luzern FactoryOEM Supplier for SV-777 silicone sealant for stone for luzern Factory

Short Description:

Description SV-777 silicone sealant for stone, is an elastomer sealant in modulus, single. Waterproof joints need to be sensitive to natural stone, glass and metal building clean appearance panel for sealing design, it to the moisture in the air after curing in contact, the formation of elastic rubber sealing performance, durability, weather resistance, good combination with most building materials.   Key Features 1. 100% silicone 2. Minimized fluid migration 3. Low dirt pick up 4. Water &...


Product Detail

Attentions

Application

Product Tags

"Based on domestic market and expand overseas business" is our development strategy for OEM Supplier for SV-777 silicone sealant for stone for luzern Factory, With the aim of "compete with good quality and develop with creativity" and the service principle of "take customers' demand as orientation", we will earnestly provide qualified products and good service for domestic and international customers.


Description

SV-777 silicone sealant for stone, is an elastomer sealant in modulus, single. Waterproof joints need to be sensitive to natural stone, glass and metal building clean appearance panel for sealing design, it to the moisture in the air after curing in contact, the formation of elastic rubber sealing performance, durability, weather resistance, good combination with most building materials.

 

Key Features

1. 100% silicone

2. Minimized fluid migration

3. Low dirt pick up

4. Water & weatherproof

5. Primerless adhesion to most building materials

6. 25% movement capability

 

Basic Application

1.Stone curtain wall sealing

2.Engineering ceramic sealing

3.Stone and other materials such as glass, metal seam sealing

4.Other uses

 

Technical data sheet

Test standard Test project Unit value
Before curing——25℃,50%R.H.
ASTM C 679 Flow, sagging or vertical flow mm 0
  VOC g/L <80
GB13477 surface drying time(25℃,50%R.H.) min 30
  Curing time(25℃,50%R.H.) Day 7-14
Sealant curing speed and operating time will have different with different temperatures and temperature, high temperature and high humidity can make sealant curing speed faster, rather low temperature and low humidity are slower.21 days after curing——25℃,50%R.H.
GB13477 Durometer Hardness Shore A 30
GB13477 The ultimate tensile strength Mpa 0.7
  Temperature stability -50~+150
GB13477 Movement capability % 25
ASTM C 1248 Pollution / oil, natural stone   No

 

Certification

25HM GB/T 23261-2009;ASTM C920-2011

 

Color

Black,White,Gray

 

Package

300ml in cartridge * 24 per box, 590ml in sausage *20 per box

 

Shelf life

12 months

 

Note

If you want the TDS or MSDS or other details, please contact with our sales person.

  • Previous:
  • Next:



  • https://www.andysautosport.com/shopbybrand/omix-ada.html

    We’re kicking off our Project YJ build by replacing our rusty old windshield frame with a new one from Omix-Ada. If you have any Jeep needs, Omix-Ada is sure to have the part with over 15,000 part numbers. This restoration starts at 1:25. From stock replacement parts to high-performance aftermarket accessories, Andy’s Auto Sport has what you need to get the looks and power your vehicle deserves.

    Source: https://www.andysautosport.com

    https://www.andysautosporttv.com

    Contact Us 1(800) 419 1152 or by email info@andysautosport.com

    Please feel free to rank our video, share it, or embed it!



    GAF – Mastering The Roof (chapter 09)

    This video demonstrates the proper installation technique for GAF starter strips; a superior alternative to starter shingles • Starter strips are important for wind resistance • Use WeatherBlocker or ProStart starter strips.

    One of the most common sources of failure in a roof system is the improper installation of starter shingles. This starter course is very important, especially for wind resistance.

    GAF offers Pro-Start and WeatherBlocker starter strips that are manufactured with a perforated line. This feature is a real time saver by eliminating the need to manually cut and cleanup shingles tabs.

    Along with convenience and savings; the Pro-Start and WeatherBlocker products utilizing advanced Dura Grip adhesive to achieve maximum protection against wind blow-offs. Now that we have covered the importance and benefits of GAF precut starter strips lets take a look at they install.

    For shingles exposure less than six inches, the use of either Pro-start or Weatherblocker starter strips can be used. For such applications; begin by separating the strip at the perforated line.

    When applying shingles with exposures greater than 6 inches, such as the Camelot collection, only full un-split WeatherBlocker starter strip can be used.

    Place the appropriate sized starter strip with the sealant facing up at the eave edge.
    For proper water drainage, Both Pro-Start and Weatherblocker starter strip require a one quarter to three quarter inches overhang at all eave and rake edges.

    Every Starter strip requires a minimum of four nails driven in a linear fashion one and a half to three inches above the shingle’s bottom edge. Begin with the first nail at a distance of one and a half to three inches from the beginning side edge. Space the remaining three nails ten to twelve inches from the previous nail, and the fourth nail one to two inches from the ending edge.

    When installing Metric dimensioned shingles, you must trim five inches off the first WeatherBlocker starter strip or three inches off the first ProStart starter strip. This critical step ensures that the starter strip butt joints and overlapping shingles butt joints are off-set a minimum of four inches. Depending on the length of the shingle being installed, A 10 to12 inch section of starter strip may periodically need to be cut and installed to meet the required 4 inch offset. Fasten the adjustment starter strip with two nails one to two inches from each side end.

    For maximum wind resistance, starter strips should be installed along all rake edges. Begin by laying the strip with the sealant side up, closest to the rake edge. Position the starter strip so that it overlaps the eave starter strip by at least three inches. As with the eave edges, the Starter strip must overhang the rake edge one quarter to three quarters of an inch. Begin the line of nail fasteners one to two inches from the side edge of the starter strip, and one and a one half to three inches from the rake edge. Complete the rake edge starter course by nailing along a vertical line every ten to twelve inches up the rake until reaching the ridge.

    Related Products

    WhatsApp Online Chat !