Leading Manufacturer for SV-9300 Fireproof silicone sealant for Lahore Importers

Leading Manufacturer for SV-9300 Fireproof silicone sealant for Lahore Importers
  • Leading Manufacturer for SV-9300 Fireproof silicone sealant for Lahore ImportersLeading Manufacturer for SV-9300 Fireproof silicone sealant for Lahore Importers

Short Description:

Description SV – 9300 Fire resistant silicone sealant is a one-component, neutral-curing silicone sealant exhibiting superior performance in applications where sealing openings in walls and floors are needed to control the spread of fire, smoke, toxic gasses, and water during fire conditions.   Where to use It is an ideal material designed for use in fire-stop systems for through penetrations and joints. This product excels in applications where greater water resistance is required e.g. ...


Product Detail

Attentions

Application

Product Tags

"Sincerity, Innovation, Rigorousness, and Efficiency" is the persistent conception of our company for the long-term to develop together with customers for mutual reciprocity and mutual benefit for Leading Manufacturer for SV-9300 Fireproof silicone sealant for Lahore Importers, With the aim of "compete with good quality and develop with creativity" and the service principle of "take customers' demand as orientation", we will earnestly provide qualified products and good service for domestic and international customers.


Description

SV – 9300 Fire resistant silicone sealant is a one-component, neutral-curing silicone sealant exhibiting superior performance in applications where sealing openings in walls and floors are needed to control the spread of fire, smoke, toxic gasses, and water during fire conditions.

 

Where to use

It is an ideal material designed for use in fire-stop systems for through penetrations and joints. This product excels in applications where greater water resistance is required e.g. curtain wall, building facade, expansion/pipe and cable joints.

 

Key Features

1. 100% silicone

2. Excellent weatherproofing and waterproofing

3. Low gas transmission rate

4. With highly efficient redundant

 

Basic Application

1.Building fire seam sealed

2.Building façade

3.cable joints

 

Technical data sheet

Test standard Test project Unit value
Before curing——25℃,50%R.H.
GB13477 Flow, sagging or vertical flow mm 0
GB13477 Operating time min 15
GB13477 surface drying time(25℃,50%R.H.) min 40-60
Sealant curing speed and operating time will have different with different temperatures and temperature, high temperature and high humidity can make sealant curing speed faster, rather low temperature and low humidity are slower.21 days after curing——25℃,50%R.H.
GB/T 531.1-2008 Durometer Hardness Shore A 20-60
GB13477 60% elongation of cementation   no damaging
GB13477 Elongation limit % 120
GB/T 24267 Sealant level   20HM
GB/T 24267 Fire prevention level   FV-0

 

Certification

GB/T 24267-2009

 

Color

Black

 

Package

300ml in cartridge * 24 per box

 

Shelf life

12 months

 

Note

If you want the TDS or MSDS or other details, please contact with our sales person.

  • Previous:
  • Next:




  • Other related videos:
    How to strip and repair tap gland-seal

    How to stop a monobloc tap outlet leaking (emergency repair)

    Earlier today I noticed some water on the floor near the kitchen sink so opened the unit and saw a bit of a leak from the main stopcock that controls flow of water from rising main into the house. Water was dripping from the gland seal. Unfortunately since this is the main way of turning off the water supply* I couldn’t isolate the actual stopcock which ironically is the isolating valve for the cold water supply. So as this was an emergency repair I had to use PTFE tape which is a product that everyone should have in their toolkit.
    Anyway – to carry out emergency repair;
    Turn off the stopcock and remove handle by unscrewing the cross-head screw in the end of shaft.
    Loosen off the gland seal retainer collar. The leak will worsen so put some old rags around it to mop up spills.
    Try to extract the old gland packing which is either rubber, fibre or leather. If the tap is in awkward place or the old seal is rock hard and too tight to remove, you then have to wrap several turns of PTFE tape around the shaft as near to the gland seal as possible.
    Now using a flat screwdriver and carefully push the tape right down into the gland seal (or what’s left of it)
    Now install the gland seal retainer collar and tighten it up.
    Now turn on the stopcock or tap/faucet and check for leaks. Ideally the old seal/packing is removed first but in the real world that sometimes doesn’t happen. If there’s still no leaks after a few hours then chances are you’ve fixed the problem. This is a ‘temporary repair’ so ultimately you will have to fit a new stopcock/tap/valve at some point. A useful tip is to regularly cycle any water supply valves, taps etc fully open and closed to keep them from sticking open or shut. Do this twice a year. Taps tend to seize more when they are fully open so it’s good practice to open them fully then back them off half a turn so the internal valve seat isn’t hard against the end stops.
    *If the main water supply stop valve is leaking you’ll either need a pipe freezing kit or hope there is a main water supply cut-off along with the water meter or supply from the mains water. Worth making a note of where the stopcocks and other valves are located on your property.

    Related Products

    WhatsApp Online Chat !